Capacity:1-20t/h
Rated thermal efficiency: 100-104%
Fixed working pressure: ≤1.6MPa
Applicable fuel:natural gas etc.
Capacity:0.7-14MW
Rated thermal efficiency:96-98%
Fixed working pressure:≤1.25MPa
Applicable fuel:Natural gas, light oil, etc.
Capacity:0.7-2.8Mw
Rated thermal efficiency: 97.2-106%
Fixed working pressure:0.1MPa
Applicable fuel:Natural gas, etc.
Capacity:2.8-7.0Mw
Rated thermal efficiency:≥105.5%
Fixed working pressure:-0.02MPa
Applicable fuel:Natural gas, etc.
Capacity:99Kw
Rated thermal efficiency:97.2-104.4%
Fixed working pressure:1.0MPa
Applicable fuel:Natural gas, etc.
Capacity:0.5-4.0 t/h
Rated thermal efficiency:98%
Fixed working pressure:≤1.25MPa
Applicable fuel:electric energy
Oct 17, 2017 · Vevey (Switzerland)/Lyon (France), le 17 octobre 2017. HOLDIGAZ has acquired a stake in the company boostHEAT to become the exclusive supplier of innovative thermodynamic boilers in Switzerland. This revolutionary technology combines natural gas and renewable energies and cuts energy consumption in half. The products will be distributed in Get Price
ASME Horizontal or Vertical Storage Tanks With ASME Steam Bundle. 4.6 - 2530 Gallons. 125 or 150 PSI. 100-2500 GPH with 120 Rise with 75 PSI Steam. 50-1000 GPH with 10 PSI Steam. Thank you for your inquiry. We Manufacture Parker Boilers and related equipment and distribute our product through our Representatives throughout the world.Get Price
Steam boilers, hot water boilers, and hot oil heaters with inputs up to 250,000,000 BTU/hr. (natural gas fired) Boiler Exhaust Application Capacity: up to 250,000 lb/hr steam Entering Gas Temps: 300°F to 800°F Heat Sink Types: boiler feedwater, makeup water, hot water return, hot water storage tank, condensate tank, process waterGet Price
The boiler undergoes thermal shock when cold water is introduced to the hot surfaces of the boiler wall and its tubes. Hotter feedwater means a lower temperature difference and less risk of thermal shock. To maintain the designed output. The lower the boiler feedwater temperature, the more heat is required in the boiler to produce steam.Get Price
MS Condenser. Steam Heating Mild Steel Condenser; Industrial Chimney. MS Heavy Industrial Boiler Chimney; Storage Tank. SS Chemical Storage Tanks; Reactor Vessel. 70KL Stainless Steel Reaction Vessel; SS Condenser. SS Steam Power Turbine Condenser; View All CategoriesGet Price
Jul 27, 2020 · Boiler, Gasfier, Steam Boiler, Steam Generator, Electric Steam Boiler, Gas Boiler, Wood Pellet Boiler, Oil Boiler, Water Boiler, Industrial Boiler Company Introduction Yangzhou Ouke Thmotechnical Technology Co., Ltd. Was founded in 2012, Yangzhou City, Jiangsu Province, with a registered capital of 10 million yuan and 28 employees.Get Price
ATTSU your supplier of industrial boilers and energy solutions. ATTSU Group builds up more than 103 years of experience manufacturing steam boilers, thermal oil heaters and hot water boilers, as well as superheated water boilers. ATTSU industrial boilers offer tailor-made and efficient energy solutions with a wide range of power from 15 to 25 Get Price
Tank Products. We offer tanks as accessories to our full line of boilers and water heaters. Applied with our instantaneous water heaters, our domestic water storage tanks provide instant hot water at peak demands; they promote stable temperature control for potable water applications and help reduce water heater cycling in laundry systems and Get Price
The GC160 series gas-fired condensing boilers offer high efficiencies in a convenient space-saving wall mounted package. Utilizing a patented parallel flow heat exchanger and state of the art premixair/gas modulation firing system for optimal combustion, GC160 boilers offer efficiencies of 93%. Units are offered in both "combi" and Get Price
•Steam cycle – Begins at the boiler where thermal energy in superheated steam is converted to mechanical energy in the propulsion turbine – Steam is then converted into condensate in the main condenser – Condensate is combined with distilled makeup water and is pumped as feedwater through heaters to aGet Price
The condensing boiler obtains extra heat from the waste gases by condensing the water vapour into liquid water. However, the efficiency of the condensing process ranges according to the temperature of the water returning to the boiler. The efficiency of a condensing boiler is constantly more than that of a non-condensing boiler.Get Price
Storage Tanks by A. O. Smith - Hot Water. A Boiler and Indirect Storage Tank Setup with Primary Loop. This is how you can set up a Gas Boiler with an indirect storage tank. This gives you alot of Domestic Hot Water along with a Closed Heating Loop Zone for one Temperature Systems - Radiant or Radiators.Get Price
asme dhw stock storage tanks, 235-534 gallon read more; asme dhw storage tanks, 80-175 gallon read more; hydronic asme buffer tanks, 40 – 139 gallonGet Price
The Prime commercial condensing gas storage water heater features a fully integrated burner and field removable 316L SS heat exchanger. (boiler, steam or solar water) Large storage water heater tanks over 150 gallon capacity and custom made stainless steel or alloy tanks have either 2" or 3" fiberglass insulation with an R value of 3.5 Get Price
SRG Surge Tank. CB-8489E. Condensate surge tank. 300-3,600 gallon capacity. On/off or variable speed pumping. The Cleaver-Brooks surge tank products provide additional storage time to handle water volume swings in condensate return to eliminate potential for overflow from a stand-alone deaerator system. Boiler Feed and Condensate Recovery Get Price
Mar 28, 2016 · Boiler feed units are generally sized for 5 minutes of net storage. You can feed your boiler for 5 to 10 minutes, depending on the load, to keep it steaming while waiting for condensate to come back. In smaller systems, up to …Get Price
Heat transfer equipment including: semi-instantaneous indirect water heaters, storage tanks, steam generators, heat exchangers and HVAC coils Dunkirk Cast Iron Steam and Water Boilers, Condensing Boilers & Indirect Water HeatersGet Price
Mar 28, 2016 · Boiler feed units are generally sized for 5 minutes of net storage. You can feed your boiler for 5 to 10 minutes, depending on the load, to keep it steaming while waiting for condensate to come back. In smaller systems, up to 150,000 sq ft EDR, 5-minute pumping capacity is a good rule of thumb. For systems larger than 150,000 sq ft EDR, 10 Get Price
An improved air-cooled vacuum steam condenser in a steam turbine cycle comprising a steam powered system comprising a turbine for converting steam energy into mechanical energy upon expansion of steam therein, a boiler for generating steam to be fed to the turbine, and a conduit arrangement coupling the boiler to the turbine and then recoupling the turbine exhaust to the …Get Price
Storage Tanks by A. O. Smith - Hot Water. A Boiler and Indirect Storage Tank Setup with Primary Loop. This is how you can set up a Gas Boiler with an indirect storage tank. This gives you alot of Domestic Hot Water along with a Closed Heating Loop Zone for one Temperature Systems - Radiant or Radiators.Get Price
9. Multiple boilers and storage tanks shall be installed with reverse return piping (as shown). 10. Mixing valves are recommended on all tanks if hot water temperature is above 119oF. 11. Expansion tank must be rated for use with potable water. 12. Use either indirect/tank sensor or system/pipe sensor mounted on common return to the boiler. 13.Get Price
Boilers - Industrial Description: THE BASICS OF INDUSTRIAL STEAM BOILER SYSTEMSHospitals, Universities, laundry services, food processing services, breweries,factories… All of these industries and numerous others rely on some type of steam boiler system to provide heat and/or hot water for their operations.Get Price
Storage Tanks by A. O. Smith - Hot Water. A Boiler and Indirect Storage Tank Setup with Primary Loop. This is how you can set up a Gas Boiler with an indirect storage tank. This gives you alot of Domestic Hot Water along with a Closed Heating Loop Zone for one Temperature Systems - Radiant or Radiators.Get Price
Feedwater Tank is designed in accordance with ASME Boiler and Pressure Vessel Code (BPVC) Section VIII Division 1, HEI Standards (Section 5.2), design conditions are given in the Data Sheet for Deaerator and Feed water Storage Tank and Site-Specific Conditions (i.e. ambient conditions, wind loads, seismology …etc) are given in General Project Get Price
A storage combi boiler merges the technology of a combi boiler with that of a system boiler. However, you don't need space to house a hot water tank as the boiler has a small storage tank built into it. This allows for high-volume water consumption but without the hot water tank that could accompany another form of boiler, such as a Get Price
Jun 30, 2021 · Best Combi Boilers– A combination or 'combi' boiler acts as both a central heating boiler and also a high-efficiency water heater in a single compact unit. Combi boilers heat water immediately from the trunks when you turn on a tap so that you do not require a cold water storage tank or a hot water storage cylinder on the rooftop.Get Price
Pre-heated boiler feed water for improved boiler efficiency. Easy access to trays and storage tank for inspection and maintenance. Internal direct contact vent condenser for minimum steam loss. Two stage deaeration for maximum efficiency. Standard design pressure of 365 kPa. Other sizes, configurations and pressure ranges also available.Get Price
The condensing boiler obtains extra heat from the waste gases by condensing the water vapour into liquid water. However, the efficiency of the condensing process ranges according to the temperature of the water returning to the boiler. The efficiency of a condensing boiler is constantly more than that of a non-condensing boiler.Get Price
SRG Surge Tank. CB-8489E. Condensate surge tank. 300-3,600 gallon capacity. On/off or variable speed pumping. The Cleaver-Brooks surge tank products provide additional storage time to handle water volume swings in condensate return to eliminate potential for overflow from a stand-alone deaerator system. Boiler Feed and Condensate Recovery Get Price
Steam boilers, hot water boilers, and hot oil heaters with inputs up to 250,000,000 BTU/hr. (natural gas fired) Boiler Exhaust Application Capacity: up to 250,000 lb/hr steam Entering Gas Temps: 300°F to 800°F Heat Sink Types: boiler feedwater, makeup water, hot water return, hot water storage tank, condensate tank, process waterGet Price